Home / Domestic
Single machine, household use
BWT BESTMIN PREMIUM M (FS24M10A00)
Water · TAS · Southern Tasmania
Supplied by TasWater · Derwent River catchments
SOFT-MINERAL-ADDITION-REQUIRED
Derwent catchment - softest capital city water in Australia. Highest corrosion risk.
Hardness (mg/L CaCO₃)
8–20
German degrees (°dH)
0.4–1.1
TDS (ppm)
10–30
Typical pH
6.8-7.3
Filter choice scales with weekly coffee volume. Pick the tier that matches your usage.
Single machine, household use
BWT BESTMIN PREMIUM M (FS24M10A00)
Up to ~10 kg coffee/week
BWT BESTMIN PREMIUM M (FS24M10A00) or Everpure ESO6 (EV960710)
10–30 kg coffee/week
Everpure ESO7 (EV960725) on QC7i Single (EV927241) or BWT BESTMIN PREMIUM M
30+ kg coffee/week, multi-group
Everpure ESO7 on QC7i Twin (EV932502) or BWT BESTMIN manifold